System Communication Unit SCU

583381.31 | System Communication Unit SCU

The System Communications Unit serves as a digital audio memory for the VARIODYN D1 system. It is possible to record and playback multiple audio data streams simultaneously.The connection to the other VARIODYN D1 modules is made via the Ethernet, and is permanently monitored.The audio storage for critical evacuation alerts and notifications is done in accordance with IEC EN 60849 in a non-volatile flash memory. Depending on the format, storage capacity is approx. two hours.Additional prerecorded audio messages such as announcements, signals, or commercial texts are stored on a hard disk. Depending on the format, storage capacity here is approx. 1000 hours.The SCU can also be used for the logging and recording of announcements. These are also stored in the memory, and logged with date, time, and activation details. The automatic buffer makes it possible to transmit announcements that cannot be played to all targets as soon as these targets become available.Connections

• Ethernet connection 100 Mbit/s

• Network connection

• 24 V DC emergency inputDisplays

• POWER-LED, HARDDISK-LED

• ERROR-LED, STAND-ALONE-LEDNote:

Not for safety-related voice messages, these must be stored in the DOM.

Part-No.:
583381.31

Features

  • EN 54-16 certified
  • Digital audio memory for VARIODYN D1
  • Networkable via Ethernet
  • Can be used for the logging and recording of announcements
  • Automatic buffer and repetition of interrupted announcements
  • 24 V DC emergency power supply

Technical Data

Rated voltage 
V AC
Input-Clipping 
Verzerrung bei -3dB unter Nennleistung (ohmsche Last) 
Indication Output voltage 
Alle Kanäle auf Batterienennspannung geladen 
Alle Kanäle werden mit Netznennspannung geladen 
Betriebsarten 
Frequency 
Versorgungsspannung_a 
Eigenschwingungsfrequenz im Ruhezustand 
Effizienz bei maximaler Last 
Eingangsimpedanz (symmetrisch) 
Eingangsempfindlichkeit 
Spannungsverstärkung 
Maximale Tragfähigkeit 
Verzerrung bei Nennleistung (ohmsche Last) 
Frequenzgang bei Nennleistung 
Vorgang Klasse D 
Temperaturkompensationsfaktor für Batterieladegerät 
Schutz vor tiefer Batterieentladung 
Starten des Ladegeräts 
Impedanz der Batteriequelle 
Strombegrenzung des Batterieladegeräts 
Kapazität der ventilgeregelten Blei-Säure-Batterie 
Zulassung/Zertifizierung VDE, Semko (EN 60934) 
Isolationswiderstand 
Stehspannung Prüfspannung 
Shutdown 
Operating life 
Kontrolllampe 
Rated current 
Signal Rausch Verhältnis 
Frequenzbereich_fr 
kHz
Leitungsspannung 
Lautsprecher_Line_Modul 
Spitzenspannungswiderstand 
max_Schaltkontaktstrom 
max_Schaltkontaktspannung 
Lastimpedanz min. 
SNR 
THD 
max_Ausgangspegel_FR 
Audio Ausgangskanäle 
Ausgabetype 
Max. Power per module 
Audio latenzy 
Output channels 
Audio Transmission Format 
Ethernet 
Output impedance 
Frequency response 
Nominal output level 
Audio output: 
Interference Voltage DistanceLine 
Interference voltage ratioMicrophone 
frequency response line 
frequency response microphone 
Nominal line input level 
Nomminal input levvel microphone 
audio input channels 
Short-circuit proof against + 24 V 
load current per output 
input resistance 
input voltage logical 0 
input voltage 1 
Input voltage 
audio storage 
Encoder/Decoder 
Sampling rate 
Voltage supply 
Power consumption 
Max. external voltage 
V DC
Voltage of loudspeaker output 
Max. number of lines per moduel 
Max Power per line 
Max. number of modules per INC 
Operation temperature 
Channel separation 
Distortion factor @ 1 kHz 
Approval 
Efficiency 
Signal to noise ratio 
Input level 
Output power *8 
Current (1 kHz sinus/1 min.) @ 24 V DC *7 
Rated current @ 230 V AC *6 
Rated current @ 24 V DC*6 
Rated frequency 
Emergency power supply 
V DC
Technology 
Operating voltage 
V DC
Operating voltage 
Current consumption @ 12 V DC 
Current consumption @ 24 V DC 
Power consumption 
24 W
Rated voltage 
90 ... 265 V AC
Output voltage 
V AC
Output current 
A
Contact load relay 
 
Data transmission speed 
Transmission distance 
Transmission range 
System input impedance 
Channel separation 
dB
Harmonic distortion at nominal level 
Sensitivity 
mV
Sound level 
dB
Impedance 
Ω
Fiber 
Ambient temperature 
-5 °C ... 45 °C
Storage temperature 
Air humidity 
< 93 % (non-condensing)
Air humidity 
Type of protection 
Housing 
Color 
gray, similar to RAL 7016
 
Mounting 
Weight 
Weight 
approx. 3 kg
 
Dimensions 
W: 483 mm H: 44 mm D: 360 mm (1 HU, 19")
 
 
Declaration of Performance 
Output current (idle) 
Output current (alarm) 
Emergency power supply 

Accessories

583486A Patch cable CAT5, 1 m yellow (ETH)

583487A Patch cable CAT5, 2 m yellow (ETH)

583488A Patch cable CAT5, 3 m yellow (ETH)

583703 Mounting set 1

Downloads

Produktdatenblatt
Ausschreibungstext

Product Data Sheet

Version: 2024-07

Language:
English
Doc extension:
pdf