Small conventional MCP Ex (i) IP 66/67, red with glass pane

804960.EX | Small conventional MCP Ex (i) IP 66/67, red with glass pane

The small compact version has detector housing, surface mount housing, transparent cover, and alarm indicator. For connection to a conventional zone for use in ex-areas. Suitable for use in damp rooms thanks to the high IP 66/67 IP protection. Surface mounting housing is provided with break-out cable entries for M20 cable glands (optional) for easy installation.

Part-No.:
804960.EX
Approval:
VdS

Features

  • High IP protection class IP 66 & IP 67
  • Triple key function (test, open, reset)
  • Plug-in terminals
  • “Out of Order” indication of an inoperative alarm by flipping over the glass pane

Technical Data

Common technical data: 
Leistungserklärung 
Rated voltage 
V AC
Rated frequency 
Rated current 
Output current 
Battery capacity 
Operating voltage 
8 ... 30 V DC
 
Operating voltage 
V DC
Operating voltage 
Quiescent current 
Lichtquelle 
Leuchtfarbe 
 
Quiescent current @ 9 V DC 
μA
Quiescent current @ 12 V DC 
Quiescent current @ 19 V DC 
μA
Quiescent current @ 24 V DC 
Quiescent current @ FACP battery 
Quiescent current @ FACP battery 
Quiescent current 
μA
Current consumption 
Current consumption 
Current consumption @ 12 V DC 
Current consumption @ 24 V DC 
Starting current 
mA
Current consumption in the case of failure 
mA
Current consumption testmode 
mA
Alarm current 
Alarm current 
Alarm current @ 9 V DC 
9 mA
Alarm current @ 12 V DC 
Alarm current @ 24 V DC 
mA
Alarm current @ 24 V DC 
Alarm current w/o communication curtain 
mA
Power consumption 
Current consumption for ext. devices 
A
Testing capacity 
Battery charging 
Heat detector response threshold 
Load factor 
Contact load relay 
Contact load 
Sound level 
dB
Sound level @ 12 V DC 
Sound level @ 24 V DC 
Sound level 
No. of detector/zone 
Circuit 
Display 
Operation indicator 
Alarm display 
red LED and yellow actuation indicator
Fault display 
Frequency of flash 
Lighting energy 
Flash color 
Luminous intensity 
 
 
Signal flashing lamp 
Range 
Connection terminal 
max. 1,5 mm² (AWG 30-14)
CO pre-alarm 
ppm
CO alarm 
ppm
Area to be monitored 
Height to be monitored 
Air velocity 
Sensitivity 
Application temperature 
-20 °C ... 70 °C
Ambient temperature 
Storage temperature 
-30 °C ... 75 °C
Air humidity 
Air humidity 
Type of protection 
 
Protection class 
Ex. protection 
Ex ib II C T4 Gb
Category 
II2G (with Ex barrier Part No. 764744/804744)
Housing 
PC ASA plastic
Material 
 
Installation 
Signal Range 
Mounting height wall 
Room width 
Category ceiling 
Mounting height ceiling 
Room diameter 
Color 
red, similar to RAL 3020
 
Weight 
approx. 255 g
Weight 
Optisches_Signalbild 
Lebensdauer_optisch 
Drehfrequenz 
Abmessungen 
Content 
Cable length 
m
Maximum sensor length 
m
Detector specification 
DIBt approval 
Specification 
 
Cable diameter 
mm
Cable entry 
Maximum tube length 
Dimensions 
W: 88 mm H: 88 mm D: 63 mm (with surface mount housing)
 
Length 
Declaration of Performance 
DoP-21415141219
Konformität 

Additional information

Use M20 cable glands with 15 mm connecting thread length and sealing ring, e.g. blueglobe by Pflitsch (cable gland Part No.: bg 820PA/sealing ring Part No.: DRF 220).

For operation with standard groups ex-barrier Part No. 764744 must be used in zone 1 and zone 2!

Scope of delivery

1 x Glass pane 704960

1 x Key 704966

1 x Surface mounting housing

1 x Transparent cover

Downloads

Produktdatenblatt
Ausschreibungstext

Product Data Sheet

Version: 2024-12

Language:
English
Doc extension: