Optical smoke detector Ex (i) IQ8Quad FM without isolator

803371.EX.IN | Optical smoke detector Ex (i) IQ8Quad FM without isolator

Scattered-light smoke detector for reliable early recognition of fires. Intelligent fire detector with decentralized intelligence, automatic function self-test, emergency mode, storage of alarm and operating data, alarm display. Soft addressing and separate operational display is only possible when operating an esserbus / esserbus-PLus IQ8Quad detector without loop isolator, especially for usage in explosion zones. Operation with individual addressing at Ex-Barrier 804744 and as standard detector at Ex-Barrier 764744.

Part-No.:
803371.EX.IN
Approval:
VdS, FM

Technical Data

Common technical data: 
Leistungserklärung 
Rated voltage 
V AC
Rated frequency 
Rated current 
Output current 
Battery capacity 
Operating voltage 
8 ... 42 V DC
 
Operating voltage 
V DC
Operating voltage 
Quiescent current 
Lichtquelle 
Leuchtfarbe 
 
Quiescent current @ 9 V DC 
μA
Quiescent current @ 12 V DC 
Quiescent current @ 19 V DC 
50 μA
Quiescent current @ 24 V DC 
Quiescent current @ FACP battery 
Quiescent current @ FACP battery 
Quiescent current 
μA
Current consumption 
Current consumption 
Current consumption @ 12 V DC 
Current consumption @ 24 V DC 
Starting current 
mA
Current consumption in the case of failure 
mA
Current consumption testmode 
mA
Alarm current 
Alarm current 
Alarm current @ 9 V DC 
18 mA
Alarm current @ 12 V DC 
Alarm current @ 24 V DC 
mA
Alarm current @ 24 V DC 
Alarm current w/o communication curtain 
mA
Power consumption 
Current consumption for ext. devices 
A
Testing capacity 
Battery charging 
Heat detector response threshold 
Load factor 
Contact load relay 
Contact load 
Sound level 
dB
Sound level @ 12 V DC 
Sound level @ 24 V DC 
Sound level 
No. of detector/zone 
Circuit 
Display 
Operation indicator 
Alarm display 
Fault display 
Frequency of flash 
Lighting energy 
Flash color 
Luminous intensity 
 
 
Signal flashing lamp 
Range 
Connection terminal 
CO pre-alarm 
ppm
CO alarm 
ppm
Area to be monitored 
110 m²
Height to be monitored 
12 m
Air velocity 
0 m/s ... 25,4 m/s
Sensitivity 
1.5% / ft to 2.4% / ft
Application temperature 
-20 °C ... 70 °C
Ambient temperature 
Storage temperature 
-24 °C ... 75 °C
Air humidity 
< 95 %
Air humidity 
Type of protection 
IP 43 (incl. base + option)
 
Protection class 
Ex. protection 
Category 
Housing 
Material 
PC / ABS
 
Installation 
Signal Range 
Mounting height wall 
Room width 
Category ceiling 
Mounting height ceiling 
Room diameter 
Color 
white, similar to RAL 9010
 
Weight 
approx. 110 g
Weight 
Optisches_Signalbild 
Lebensdauer_optisch 
Drehfrequenz 
Abmessungen 
Content 
Cable length 
m
Maximum sensor length 
m
Detector specification 
EN 54-7 : 2006
DIBt approval 
Specification 
 
Cable diameter 
mm
Cable entry 
Maximum tube length 
Dimensions 
Ø: 117 mm H: 49 mm (62 mm incl. base)
 
Length 
Declaration of Performance 
DoP-20914130701
Konformität 

Accessories

805590.IN Standard detector base for IQ8Quad FM

Additional information

Intrinsically safe fire detection equipment is defined as "equipment and wiring which is incapable of releasing sufficient electrical or thermal energy under normal or abnormal conditions to cause ignition of a specific hazardous atmosphere mixture in its most easily ignited concentration”. This basically means that intrinsically safe equipment and wiring operates using electrical and thermal energy below the level that would be required to spark an explosion in a hazardous area such as an oil refinery, Oil Rigs/Platforms, FPSO’s.

Fully addressable devices for installation in hazardous areas with direct connection of the Ex barrier (Part No. 804744) on the loop, without spending a loop address for the connection via a transponder as in case of the conventional connection.

Additional detectors for the explosion zones can be found in the chapters manual call points and special detectors.

All of the following FM approved IQ8Quad intrinsically safe fire detectors must be operated with the Part No. 805590.IN base. In the case of operation in standard zones, no individual addressing is possible!

For usage in zone 1 and zone 2 in case of operation

- with individual addressing the Ex barrier Part No. 804744,

- in conventional zones the Ex barrier Part No. 764744 must be used!

The Ex barrier separates intrinsically safe and non-intrinsically safe circuits before the explosion prone area to be monitored (explosion zone).

Scope of delivery

Without detector base

Downloads

Produktdatenblatt
Ausschreibungstext

Brochure Ex products

Version: 05.2016

Language:
German
Part No.:
797352
Doc extension:
pdf
File Size:

Brochure Ex Products

Version: 05.2016

Language:
English
Part No.:
797352.G0
Doc extension:
pdf
File Size:
1681 kB

Product Data Sheet

Version: 2024-12

Language:
English
Doc extension:
pdf