IP66 housing for OSID image sensor (imager)

761331 | IP66 housing for OSID image sensor (imager)

The OSID linear smoke imaging detector uses a sophisticated pixel-level mathematical evaluation algorithm to compare the infrared (IR) and ultraviolet (UV) gray levels on pixel level in the CMOS imager.

The multi-emitter imager will analyze the signals from up to 7 emitters.

The system uses dual wavelengths so that different particle sizes can be detected and distinguished. While there is a strong interaction between the shorter UV waves for both small and large particles, the longer IR waves are only affected by larger particles.

Through the algorithmic evaluation of the attenuation of both wavelengths, the detector is able to distinguish large dust particles from smoke, building movements and entering solid bodies as possible making the detector highly resistant to nuisance alarms.

3D volumetric coverage

Receivers with a viewing angle of 80° have an imaging chip that allows up to seven transmitters per receiver. Unlike conventional linear detectors, where each receiver must be wired, only the wiring of the receiver is necessary here.

Since the different transmitters can be easily adapted to obstacles along the walls and arranged at different heights, an optimum coverage achieved. The beam length of the 80°-imager ranges from 8 to 150 m. The horizontal and vertical viewing angles of the receivers allow 3D coverage.

Furthermore, optical filtering, high-speed image acquisition and intelligent software algorithms ensure that the detector processes images and thus ultimately offers the highest possible degree of stability and sensitivity, while at the same time offering greater insensitivity to extreme lighting fluctuations.

The OSID detector (receiver) has an internal event memory for up to 10.000 events for possible alarm and fault analysis.

The connection to the esserbus loop is made in the usual way via the esserbus transponder. It is also easy to reset using this esserbus transponder by programming the relays on it as reset relays using the tools 8000 programming and service software and setting the reset time individually.

Range overview:

Light source: OSID standard light source

Range (max. 1 light source):

OSI-10 Receiver 7°, range 30 ... 150 m

OSI-90 Receiver 80°, range 6 ... 34 m

Light source: OSID high power light source

Range (max. 7 light sources):

OSI-10 Receiver 7°, not compatible

OSI-90 Receiver 80°, range 12 ... 68 m

Part-No.:
761331

Features

  • Simple & easy --> low installation costs
  • High tolerance to vibration, object intrusion and strong airflow
  • Reliable distinction between real smoke and other disturbing influences such as dust, steam, birds and insects and much more
  • For application with high temperature changes
  • High tolerance to false alarms
  • Simple DIP switch configuration
  • Automatic commissioning
  • Three selectable alarm thresholds
  • Wired and battery powered transmitter/emitter available
  • 3D volumetric coverage
  • Pollution monitoring
  • 2° building movement allowed

Technical Data

Operating voltage 
Contact Ausgänge 
Contact Current 
Sensoren pro Hub 
Sensoren pro Controller 
Hubs pro Controller 
Angesaugte Lufttemperatur 
Länge der Abzweigleitung 
Lineare Rohrlänge 
Ansaugöffnungen 
Operation temperature 
Anzahl_der_Relaisausgänge 
Indication Output voltage 
Nominal frequency 
Hz
Rated voltage 
 
Operating voltage 
V DC
Operating voltage 
Voltage supply 
Quiescent current 
Quiescent current @ 9 V DC 
Quiescent current @ 12 V DC 
Quiescent current @ 19 V DC 
Quiescent current @ 24 V DC 
Ruhestrom @ 28 V DC_comp 
Quiescent current @ FACP battery 
Quiescent current @ FACP battery 
 
Current consumption 
Alarmstrom @ 28 V DC_comp 
Current consumption @ 12 V DC 
Current consumption @ 24 V DC 
Current consumption 
Power consumption @ 5 V DC 
Power consumption @ 12 V DC 
Power consumption @ 24 V DC 
Alarm current @ 9 V DC 
Alarm current @ 12 V DC 
Alarm current @ 24 V DC 
Starting current @ 24 V DC 
Starting current 
Current consumption in the case of failure 
Output current 
A
Power consumption 
Current consumption for ext. devices 
A
Battery capacity 
Contact load 
Contact load relay 
Sensitivity 
Sound level 
Sound level @ 24 V DC 
Display 
Frequency of flash 
Hz
Lighting energy 
Range 
Connection terminal 
Maximum tube length 
Area to be monitored 
Height to be monitored 
Alignment angle 
Unempfindlichkeit gegenüber Gebäudebewegungen 
Air velocity 
Application temperature 
Response temperature 
Ambient temperature 
-25 °C ... 60 °C
Storage temperature 
Wavelength 
nm
Connection 
Sampled Air Temperature 
Air humidity 
Air humidity 
Ex-category 
Ex. protection 
Type of protection 
 
Housing 
Type 
Material 
 
Color 
Weight 
Weight 
 
Luftfeuchtigkeit 
Cable length 
m
Maximum sensor length 
m
Rückseitige Bodenplatte 
mm
Detector specification 
EC-type examination certificate 
Specification 
 
Dimensions 
W: 241 mm H: 194 mm D: 127 mm
 
 
Declaration of Performance 
Approval 

Downloads

Produktdatenblatt
Ausschreibungstext

Product Data Sheet

Version: 2024-07

Language:
English
Doc extension:
pdf