FACP ES Line for 8 zones, Dutch

809041.08 | FACP ES Line for 8 zones, Dutch

With 8 detector zones, foil: Dutch.

Part-No.:
809041.08
Approval:
VdS

Features

  • 8 sensor groups with up to 30 sensors in each sensor group (conventional panel supports up to 240 conventional devices in total)
  • Large LCD display with 8 rows x 40 characters
  • Integrated sensor group single display
  • Optimized commissioning, maintenance and operation
  • Simple configuration and programming on the keypad
  • Four relays, freely programmable, non-monitored, potential free, max. 30 V DC / 2 A or 60 V DC / 1 A
  • 2 outputs for connecting acoustic or optical sounders according to EN 54-13 (29 V DC/ max. 500 mA)
  • 1 interface to a transmission unit for fire alarm routing equipment (FARE) (12 V DC / max. 200 mA)
  • 1 interface to a transmission unit for fault warnings (12 V DC / max. 200 mA)
  • 1 standard interface extinguisher for fire control system type C according to DIN EN 54-2
  • RS485 for connecting to fire brigade operating panel and fire brigade display panel
  • 1 output UBext 29 V / 0.5A, for power supply of external bus users
  • 72 h emergency current bridge
  • “Delay of relaying” function (PM operating mode according to DIN VDE 0833-2 for preventing false alarms, delay / verify)
  • “2-detection dependency” function (TM operating mode according to DIN VDE 0833-2 for preventing false alarms), alternatively programmable as intermediate alarm storage or 2-zone dependency between the detector zones
  • Operating panel with alphanumerical display
  • Large LCD display with 8 rows x 40 characters
  • Alarm counter for up to 10,000 trips
  • Event memory for up to 10,000 events

Technical Data

Rated voltage 
230 V AC
Zertifizierung 
Leistungsaufnahme und DAS-Ausgang unter 48 V 
Leistungsaufnahme und DAS-Ausgang unter 24 V 
DAS Ausgangsspannung (nur positive Sicherheit) 
Eingang der Spannungsversorgung 
Spannungsfernbedienungseingang mit Spannungsemission 
Spannung_Fernbedienungseingang mit Stromunterbrechung 
Rated voltage 
Rated frequency 
50 Hz ... 60 Hz
Nominal frequency 
Hz
Rated current 
0,84 A
Operating voltage 
Operating voltage 
V DC
Operating voltage 
Output voltage 
29 V DC
Rated current 
Output voltage 
Output current 
Output current 
Quiescent current 
approx. 100 mA
 
Quiescent current @ 12 V DC 
Current consumption 
Current consumption 
Current consumption @ 12 V DC 
Current consumption @ 24 V DC 
Alarm current @ 12 V DC 
Current consumption for ext. devices 
A
Belastbarkeit pro Ausgang 
Power consumption 
W
Battery 
Battery capacity 
max. 2 x 12 Ah
 
Resolution 
Contact load relay 
Contact load 
Connection terminal 
Holding power 
N
Cable entry 
Application temperature 
Ambient temperature 
-5 °C ... 45 °C
Storage temperature 
-5 °C ... 50 °C
Ambient conditions 
Air humidity 
Air humidity 
< 95 %
Type of protection 
IP 30
Housing 
ABS, 10 % glass fiber reinforced, V-0
Material 
Color 
gray, similar to Pantone 538
 
Color front plate 
Height 
Weight 
Weight 
approx. 5 kg (without batteries)
 
FO-Connector 
Cable length 
m
Cable 
Dimensions 
W: 450 mm H: 320 mm D: 185 mm
 
 
Declaration of Performance 
DoP-21233141217
Specification 
Approval 
Voltage supply 
Ausgangsspannung typisch 
Power output 
W
Stromaufnahme max. 
Akkumulator 
Inputs 
Outputs 
Luftfeuchtigkeit 
Montageart 
Schaltleistung max. 
Schraubklemmen Drahtquerschnitt max. 
Stromaufnahme typisch 
Versorgungsspannung Alarmgeberkreise 
Ausgangsstrom max. 
Versorgungsspannung 
V
Versorgungsspannung_a 
Stromaufnahme bei 24 V 
Nennausgangsleistung 
min. Ausgangsstrom 
max. Ausgangsstrom 

Accessories

FX808460 Touchscreen operating unit, surface mount

FX808461.10 Touchscreen operating unit, cavity wall mount

Additional information

Detector Series ES Detect and conventional devices are compatible with this FACP.

Due to its nature, this article contains components classified as dangerous goods. Please clarify in advance with your forwarding agent if he accepts the transport of dangerous goods and if necessary observe the import regulations. The dangerous goods class for road transport or air transport is as follows:

UN-No. UN3090

ADR-Class 9

Scope of delivery

FACP with system software including installation material, installation/commissioning/operating manuals, log book for FAS, but without batteries.

Product Data Sheet

Version: 2024-07

Language:
English
Doc extension:
pdf